Serial number | Device Name | Function Introduction | |
1 | Low water tank | Demonstration system water source | |
2 | Roof water tank | Temporary high pressure system early water source | |
3 | Fire control cabinet | Fire protection system electrical control | |
4 | Fire pump | Fire fighting system booster water supply | |
5 | Voltage boosting and stabilizing equipment | Fire protection system pressurization and stabilization | |
6 | Fire hydrant fire extinguishing module | Demonstrate the composition and working principle of fire hydrant fire extinguishing system | |
7 | Automatic sprinkler module | Organic glass cabinet | Nozzle working area |
Wet sprinkler module | Wet sprinkler fire extinguishing system structure and action demonstration | ||
Dry sprinkler module | Dry sprinkler fire extinguishing system structure and action demonstration | ||
Pre-action automatic sprinkler module | Pre-action sprinkler system structure and operation demonstration | ||
Deluge sprinkler module | Structure and action demonstration of sprinkler fire extinguishing system | ||
Electric control cabinet | Automatic sprinkler system electrical control | ||
8 | Fire alarm linkage system | Fire alarm linkage system |
Serial number | name | unit | quantity | Remark |
1 | Point-type photoelectric smoke detector | set | 1 | Intelligent, electronic coding, built-in integrated chip, with automatic compensation capability, fault self-diagnosis function and water vapor false alarm function, 360-degree visible indicator light, used in conjunction with TX3986 base. |
2 | Point type heat fire detector | set | 1 | Intelligent, electronic coding, built-in single chip microcomputer , used with TX3980 base, indicator light is visible 360 degrees, category: A2R. |
3 | Fire sound and light alarm | set | 1 | Electronic coding, high-brightness LED light source, can achieve sound and light separation, plug-in installation, must be used with TX6300-DZ base. |
4 | Manual fire alarm button | set | 1 | Electronically coded, recoverable, plug-in installation, with telephone jack, for use with TX3983 base. |
5 | Input and output modules | set | 1 | Electronic coding, plug-in installation, single input and output interface. Output contact capacity: DC24V/1.5A. With line detection function, used with TX3208-DZ. |
6 | Input Module | set | 1 | Electronic coding, plug-in installation, can receive passive normally open contact signals of equipment, and has line detection function, used in conjunction with TX3200-DZ. |
7 | Output Module | set | 1 | Used with TG3100 broadcasting system, electronic coding, single speaker disconnection detection function, plug-in installation, two-way switching, used for switching between fire broadcasting and normal broadcasting, used in conjunction with TX3214B-DZ. |
8 | Fire display panel | set | 1 | Plug-in structure, Chinese character LCD display, can cyclically display up to 1024 alarm messages, DC24V (non-polarity) power supply, bus communication mode. |
9 | Fire hydrant button | set | 1 | Electronic coding, recoverable, plug-in installation, can start the fire pump by pressing the fire hydrant button, the answer indicator light will light up after the fire pump starts, super waterproof performance. Used with TX3982 base. |
10 | Combustible gas detector (coded) | set | 1 | Electronic coding, can detect natural gas. |
11 | Handheld encoder | set | 1 | Liquid crystal display is used for coding of all coded front-end devices of our company's automatic fire alarm systems, TN3 series fire telephone systems, TS6 series emergency lighting and evacuation indication systems, TM3 series fire door monitoring systems, TE3 series electrical fire monitoring systems, TP3 series fire equipment power supply monitoring systems, TR3 series combustible gas systems, etc. |
12 | Fire alarm controller (linkage type) | tower | 1 | Vertical cabinet type, including 1 TX6950 standard vertical cabinet, 1 loop, which can be expanded to 6 loops at most, with a total of 242 alarm linkage points, including a 128-point bus operation panel (which can be expanded to 320 points at most through TX6502/TX6503), 6-way multi-line control panel (which can be expanded to 56 points at most through TX6520), 1 TD0816 fire linkage power supply (power linkage output maximum 8A), and 2 12V/24AH backup batteries for controller and linkage power supply. |