DYLY-LM fire linkage control center and fire extinguishing system experimental platform
Release time:2024-06-19 23:30viewed:times
1. System Overview
The fire linkage control center and sprinkler fire extinguishing system tr*ning device are designed according to the " Building Fire Design Code". The system has a fire control linkage center, a fire broadcast telephone center, a fire sprinkler system, and a typical structure of a fire hydrant system. It can complete demonstration tr*ning projects and fire management centers such as fire detection, fire alarm, on-site fire extinguishing, and gas fire extinguishing alarm. At the same time, it can clearly show the typical equipment composition and system working principle of the sprinkler fire extinguishing system. Through the operation and learning of the device, students can have a comprehensive understanding of the structure of the sprinkler fire extinguishing system in the building
. The sprinkler system and the linkage control center system are connected to realize network control, and the detector is connected to the linkage center to realize manual and automatic control; the gas fire extinguishing alarm system is connected to the operation management center and connected to the broadcast telephone center at the same time, fully realizing the intelligent building design, mastering the application of the m*n fire extinguishing equipment inside the building, and being familiar with the structure and principle of fire extinguishing equipment such as wet alarm valves, water flow indicators, and pressure switches in building fire protection. Understand the linkage operation and settings of the fire control center, the control and operation settings of the broadcast telephone center, understand the principles and debugging of the modern building fire linkage equipment system, and be familiar with the control principle and working process of fire protection. It is suitable for practical teaching of professional courses such as "Building Fire Extinguishing System", "Building Water Supply and Dr*nage System", and "Building Fire Control System".
II. Product Features
(1) It has a test sprinkler start function. When the automatic control system f*ls, the sprinkler pump can be manually started;
(2) It has its own controller, which can realize local control and fire alarm linkage control;
(3) The m*n components such as the model frame and water tank are all made of st*nless steel devices;
III. Technical parameters and configuration
Basic configuration and parameters
1. Sprinkler fire extinguishing system configuration
The m*n components such as the model frame and water tank are all made of st*nless steel devices to ensure that they will not rust or age, simulating the sprinkler fire extinguishing system of a two-story building; the model system is m*nly composed of typical water sprinkler fire extinguishing equipment such as sprinkler pump, *r pressure tank, wet alarm valve, hydraulic alarm, delay, pressure switch, water flow indicator, closed nozzle, test valve, fire detector, fire alarm, etc., which can vividly simulate the typical structure of the water fire extinguishing system in the building.
2. Fire hydrant equipment
(1) It consists of a water gun, a water hose, and a fire hydrant. The pressure stabilizing device is m*nly composed of a small imported *r pressure tank, a fire hydrant pump unit, a fully automatic sprinkler pump unit, pipe valve accessories and a control cabinet, among which the fire hydrant pump unit constitutes a fire hydrant sprinkler system.
(2) Water supply network, consisting of an inlet pipe fire m*n pipe, a fire riser and related valves and valve parts. The water supply network and related valve accessories are made of materials required by the fire system water supply specification to meet the pressure bearing capacity specified by the fire water supply system;
3. Power control panel (all st*nless structure)
provides AC power: three-phase AC 380V 50Hz, with overcurrent protection
4. Fire alarm controller (linkage type)
5. Fire display panel
6. Detector
Equipped with three types of detectors such as combustible gas detectors, intelligent photoelectric smoke detectors and differential temperature fire detectors.
7. Input module, control module Input module
M*nly used for signal detection such as pressure switches, and control module is m*nly used for linkage equipment such as water pumps.
8. Manual alarm button
When a fire occurs, press the organic glass sheet, the fire alarm light of the button will light up, and send a fire alarm signal to the controller at the same time;
9. Fire hydrant button
When a fire occurs, press the pressure controller to alarm, light up the fire alarm indicator light (red), and output a set of external control empty contacts at the same time. When starting the fire pump, connect the pump start answer signal, the pump start indicator light up (green), and when resetting, slide down the sliding cover and press the reset button.
10. Sound and light alarm, alarm bell
When a fire occurs on site, after receiving the control signal, a strong sound alarm signal is issued to remind the on-site personnel to pay attention.
11. Electronic encoder
Complete the encoding of on-site equipment, change of equipment type and sensitivity, etc.
12. Broadcast recording and playback unit
Fire broadcast recorder and player, broadcast ceiling speaker
13. Power amplifier unit
Fire constant voltage power amplifier, background sound source power amplifier
14. Fire telephone system
Bus telephone communication panel, telephone extension, telephone module, etc.
15. Gas fire extinguishing system
The gas fire extinguishing system model includes fire linkage equipment such as smoke detectors, manual alarm buttons, sound and light alarms, deflation display screens, manual and automatic conversion switches, etc., to realize the alarm function of communication linkage with the fire sprinkler alarm host.
16. Virtual simulation software for electrical installation of building buildings and intelligent buildings Based on unity3d design, users can choose different sizes of interactive interfaces according to computer configuration, and can choose six levels of image quality. The model in the software can be rotated 360°, enlarged, reduced, and translated. There are assistant prompts during the use of the software, as follows: A. Wet alarm system 1. System overview: Overview of wet alarm system
2. Equipment recognition: It has the best viewing angle, equipment det*ls (displaying the introduction or parameters of the equipment), exercises (built-in 6 multiple-choice questions, with prompts for correct and incorrect choices), and schematic diagrams (you can enter the equipment from the schematic diagram). The equipment includes: sprinklers, water flow indicators, signal butterfly valves, exhaust valves, fire alarm controls, high-pressure gauges, high-level water tanks, Wia control cabinets, pressure-stabilizing tanks, flow switches, terminal water testing devices, dr*nage facilities, water pump connectors, hydraulic alarms, time delays, wet alarms, butterfly valves, check valves, fire pumps, safety pressure-stabilizing valves, and fire water tanks.
3. Principle display: Displays the working principle of the wet alarm system, 3D animation demonstrations, and semi-transparent 3D models, so you can see the internal water flow. Equipped with practice module (built-in 4 multiple-choice questions, with prompts for correct and wrong choices)
4. Design layout: There are multiple-choice questions and calculation questions, each of which is scored, and the correct answer and score will be displayed after submission
B. Gas fire extinguishing system
1. System overview: Overview of gas fire extinguishing system
2. Equipment cognition: It is equipped with the best viewing angle, equipment det*ls (displaying the introduction or parameters of the equipment), practice (built-in 8 multiple-choice questions, with prompts for correct and wrong choices), schematic diagram (you can enter the equipment from the schematic diagram). The equipment includes: nozzle, HFC-227 storage bottle, bottle head valve, heptafluoropropane check valve, high-pressure hose, gas check valve, safety valve, weighing alarm, electromagnetic starter, selection valve, smoke alarm, fire alarm controller.
3. Principle display: Display the working principle of the gas fire extinguishing system, 3D animation demonstration, 3D model is semi-transparent, and the internal gas can be seen. Equipped with practice module (built-in 3 multiple-choice questions, with prompts for correct and wrong choices)
4. Design and layout: There are 6 multiple-choice questions, each with scores, and the correct answer and score will be displayed after submission
. C. Escape drill: Teaching in the form of fun games, escape from the burning room within a limited time, and wrong choices will directly enter the score interface.