DY-234 Hydrolysis Acidification Tank Training Platform
Release time:2024-06-24 01:00viewed:times
1. Experimental purpose:
1. To deepen the understanding of the process for "printing and dyeing wastewater" or other wastewater.
2. To master the performance and test technical data of the process operation and use reliable data in production.
3. To enable operators to improve theoretical and practical knowledge.
2. M*n technical indicators and parameters:
1. Ambient temperature: 5℃~40℃
2. Processed water volume: 30~50L/h,
3. Device dimensions: 600mm×400mm×1500mm,
4. Working power supply: AC220V±10%, 50Hz, single-phase three-wire system, power 200W, safety protection: with grounding protection, leakage protection, overcurrent protection
3. M*n configuration:
1. 1 raw water tank: white PP board material, thickness 10mm, 400×400×500mm, a dr*n valve is installed on the bottom plate to facilitate water dr*nage;
2. 1 clean water tank: white PP board material, thickness 10mm, 400×400×500mm, a dr*n valve is installed on the bottom plate to facilitate water dr*nage;
3. Equipped with 1 raw water tank stirring motor , 1 set of 304 st*nless steel stirring paddle; (power 25W, speed 120rpm), (including 1 speed regulator)
4. 1 hydrolysis acidification tank, made of transparent plexiglass, with a wall thickness of 10mm, 500×350×500mm; (including 1 batch of fillers)
5. 1 anti-corrosion lifting magnetic water pump, flow rate: 16~19 (L/min), head: 2.7~3.4 (m), power 20W;
6. 1 stirring motor, 1 set of 304 st*nless steel stirring paddle; (power 25W, speed 120rpm), (including 1 speed regulator)
7. Flow measurement and regulation: 1 rotor flowmeter (LZS-15, range 10~100L/h)
8. Power control system: 1 double-sided matte dense-gr*ned plastic-sprayed electric control box, leakage protector (Delixi brand), voltmeter, lockable push button switch, wire pipe, etc.
9. Matching UPVC connecting pipes and valves (Zhongc* brand).
10. St*nless steel frame test bench (30mm×30mm st*nless steel square tube, with casters for universal wheels with locking feet).
11. Virtual simulation software for electrical installation of building and intelligent building Designed based on unity3d, users can choose different sizes of interactive interface according to computer configuration, and can choose six levels of image quality. The model in the software can be rotated 360°, enlarged, reduced, and translated. There are assistant prompts during the use of the software, as follows: A. Wet alarm system 1. System overview: Overview of wet alarm system 2. Equipment recognition: It has the best viewing angle, equipment det*ls (displaying the introduction or parameters of the equipment), exercises (built-in 6 multiple-choice questions, with prompts for correct and wrong choices), schematic diagram (you can enter the equipment from the schematic diagram). Equipment includes: sprinkler, water flow indicator, signal butterfly valve, exhaust valve, fire alarm control, high pressure gauge, high-level water tank, Weiya control cabinet, pressure regulating tank, flow switch, terminal water test device, dr*nage facilities, water pump connector, hydraulic alarm, delay, wet alarm, butterfly valve, check valve, fire pump, safety pressure regulating valve, fire water pool. 3. Principle display: Display the working principle of the wet alarm system, 3D animation demonstration, 3D model is semi-transparent, and the internal water flow can be seen. Equipped with exercise module (4 built-in multiple-choice questions, both correct and wrong choices are prompted) 4. Design layout: There are multiple-choice questions and calculation questions, each question is scored, and the correct answer and score are displayed after submission B. Gas fire extinguishing system 1. System overview: Overview of gas fire extinguishing system 2. Equipment cognition: It is equipped with the best viewing angle, equipment det*ls (displaying the introduction or parameters of the equipment), exercises (8 built-in multiple-choice questions, both correct and wrong choices are prompted), and schematic diagram (you can enter the equipment from the schematic diagram). Equipment includes: nozzle, HFC-227 storage bottle, bottle head valve, HFC-227 one-way valve, high-pressure hose, gas one-way valve, safety valve, weighing alarm, electromagnetic starter, selector valve, smoke alarm, fire alarm controller. 3. Principle display: Demonstrate the working principle of the gas fire extinguishing system, 3D animation demonstration, 3D model is semi-transparent, and the internal gas can be seen. Equipped with practice module (3 built-in multiple-choice questions, with prompts for correct and wrong choices) 4. Design layout: There are 6 multiple-choice questions, each with scores, and the correct answer and score will be displayed after submission. C. Escape drill: Teaching in the form of fun games, escape from the burning room within a limited time, and wrong choices will directly enter the score interface.