ZR-158 type Activated carbon adsorption experimental device (6 pieces) |
M*n parameters and configuration: Activated carbon adsorption column size: Φ35mm×1000mm 6 pieces, overall dimensions: 1000mm×600mm, power supply 220V power 200W, configuration: Each set of test equipment is composed of three activated carbon columns connected in series, two groups, consisting of plexiglass tubes, activated carbon layers, partitions, rubber races, 1 water distribution tank, 1 water pump, 2 water inlet flow meters, 1 set of activated carbon fillers, 1 electric control box, leakage protection switch, push button switch, connecting pipes and ball valves, and a st*nless steel stand with movable wheels. |
ZR-243 type Multifunctional activated carbon adsorption and softening device |
M*n parameters and configuration: Processed water volume: 50-70L/h, device dimensions: 23000mm×500mm×2100mm, power supply 220V, power 400W, configuration: 1 set of organic glass activated carbon adsorption column, 1 set of organic glass ion exchange column, 1 intermediate water tank, 1 soft water tank, 1 dr*nage trough, 1 polypropylene salt liquid tank, 1 water pump, 2 water inlet flow meters, 1 set of activated carbon filler, 1 set of resin filler, 1 electric control box, leakage protection switch, push button switch, connecting pipes and ball valves, st*nless steel stand with movable wheels, etc. |
ZR-244 type Activated carbon adsorption purification device (4-column gas-water backwash) |
M*n parameters and configuration: Activated carbon adsorption column: Φ100mm×2000mm (4 groups), device dimensions: 1100×800×2200mm, power supply 220V, power 300W, configuration: 4 sets of activated carbon adsorption columns, equipped with 4 sets of activated carbon layers, 2 water pumps, 1 fan, 4 large filter caps, 20 copper valve sampling ports, 4 water inlet flow meters and backwash flow meters, 1 PVC water distribution tank, 1 electric control box, leakage protection switch, push button switch, connecting pipes and ball valves, st*nless steel stand with movable wheels, etc. |
ZR-572-I activated carbon adsorbs sulfur dioxide in the gas |
M*n parameters and configuration: experimental gas volume 10~15m3/h, SO2 purification efficiency greater than 95%, activated carbon adsorption tower size Φ100×1000mm, device dimensions: length 1200 width 400 height 1800mm, power supply: 220V, power 500W, configuration: including 1 set of small organic glass buffer, 1 set of three-stage activated carbon adsorption tower, 1 set of t*l gas washing tank, 1 set of adsorption tank, 1 set of activated carbon filler, 1 fan, 1 set of SO2 gas and cylinder (10 liters), 1 pressure reducer, 1 gas flow meter, 1 electric control box, leakage protection switch, push button switch, 1 batch of connecting pipes, st*nless steel bracket with movable wheels, etc. |
ZR-572-II data acquisition activated carbon adsorption purification of SO2 in gas |
M*n parameters and configuration: experimental gas volume 10~15m3/h, SO2 purification efficiency greater than 95%, activated carbon adsorption tower size Φ100×1000 mm, device dimensions: length 1200mm width 400mm height 1800mm, power supply: 220V power 500W, configuration: 1 set of microcomputer SO2 inlet and outlet concentration detection, 1 set of wind pressure detection, 1 set of 11-inch color LCD touch screen, 1 set of data processing and analysis system, 1 communication interface, 1 set of online temperature and humidity detection, 1 set of micro printer, including 1 set of small organic glass activated carbon gas generating device, 1 set of three-stage activated carbon adsorption tower, 1 set of t*l gas washing tank, 1 set of activated carbon adsorption tank, 1 set of activated carbon filler, 1 fan, 1 gas flowmeter, 1 set of SO2 gas and cylinder (10 liters), 1 pressure reducer, 1 SO2 gas flowmeter, 1 electric control box, leakage protection switch, push button switch, 1 batch of PVC connecting pipes, st*nless steel bracket with movable wheels, etc. |
ZR-576-I Activated carbon moving bed adsorption experimental device (automatic control, full set of st*nless steel, with activated carbon regeneration) |
M*n parameters and configuration: experimental gas volume 4m3/h, organic matter purification efficiency 90%, regeneration heater power: 2kw adsorber diameter: Φ100mm height 1300mm device dimensions: 2100×450×2300 mm, power 220V power 3200W, configuration: the equipment is equipped with 1 set of three-stage activated carbon moving bed adsorber, 1 set of organic gas generator, 1 set of gas mixing buffer, 2 fans, 1 suction fan, 2 sets of activated carbon moving motors, 2 sets of speed regulators, 1 set of heaters, 1 set of temperature control system, 1 set of coolers, 1 set of cooling system, 1 set of fire retardant buffer box, 8 sets of temperature control sensors , 5 sets of sampling ports, 1 instrument control cabinet. It is composed of 1 set of methyl alcohol gas and cylinder (8 liters), 1 pressure reducer, 2 gas flow meters, 1 electric control box, leakage protection switch, push button switch, 1 batch of st*nless steel connecting pipes and ball valves, and st*nless steel bracket with moving wheels. |
ZR-576-II data acquisition activated carbon moving bed adsorption experimental device (automatic control, full set of st*nless steel, with activated carbon regeneration) |
M*n parameters and configuration: experimental gas volume 4m3/h, purification efficiency of organic matter 90%, regeneration heater power: 2kw st*nless steel adsorber diameter: Φ100mm height 1000mm device size: 2100mm×450mm×2300 mm, power supply 220V power 3200W, configuration: 1 set of microcomputer formate gas inlet and outlet concentration detection, 1 set of online wind pressure detection, 1 set of online temperature and humidity detection, 1 set of 11-inch color LCD touch screen, 1 set of data processing and analysis system; 1 set of computer communication interface, 1 set of micro printer, configuration: the equipment is equipped with 1 set of three-stage activated carbon moving bed adsorber, 1 set of organic gas generating device, 1 set of gas mixing buffer, 2 sets of fans, 1 set of suction fan, 2 sets of activated carbon mobile motors, 2 sets of speed regulators, 1 set of heater, 1 set of temperature control system, 1 set of cooler, 1 set of cooling system, 1 set of fire-blocking buffer box, 8 sets of temperature control sensors, 5 sets of sampling ports, and 1 automatic instrument control cabinet. It consists of 1 set of acetone gas and cylinder (8 liters), 1 pressure reducer, 2 gas flow meters, 1 electric control box, a leakage protection switch, a push button switch, 1 batch of st*nless steel connecting pipes and ball valves, and a st*nless steel bracket with movable wheels. |
ZR-577-I Activated Carbon Temperature Variable Adsorption Experimental Device (Automatic Control St*nless Steel) |
M*n parameters and configuration: adsorption efficiency 90%, gas processing volume: 2-4m3/h, st*nless steel adsorber outer diameter: Φ100mm height 1000mm; adsorption temperature 0-70 degrees, regeneration heater power: 2kw, device dimensions: 2200mm×500mm×2000 mm, power 220V power 4000W, configuration: 1 set of st*nless steel adsorption tower, 1 set of water bath, 1 set of buffer cylinder, 1 set of heater, 2 sets of gas flow meters, 2 vortex jet fans, 1 set of temperature control system, 1 set of cooler, 1 set of cooling system, 1 set of fire-retardant buffer box, 6 sets of temperature control sensors, 6 sets of manual sampling ports, 6 programmable controllers, 1 set of methyl alcohol gas and cylinder (8 liters), 1 pressure reducer, 1 electric control box, leakage protection switch, push button switch, 1 batch of st*nless steel connecting pipes and ball valves, st*nless steel bracket with movable wheels, etc. |
ZR-577-II data acquisition activated carbon temperature swing adsorption experimental device (automatic control, full set of st*nless steel) |
M*n parameters and configuration: adsorption efficiency 90%, gas processing volume: 2-4m3/h, st*nless steel adsorber outer diameter: Φ100mm height 1000mm, adsorption temperature 0-70 degrees, regeneration heater power: 2kw, device dimensions: 2200×500×2000 mm, power supply 220V Power 4000W, configuration: 1 set of microcomputer methyl acetylene gas inlet and outlet concentration detection, 1 set of online wind pressure detection, 1 set of online temperature and humidity detection, 1 set of 11-inch color LCD touch screen, 1 set of data processing and analysis system; 1 set of computer communication interface, 1 set of printer, 1 set of st*nless steel adsorption tower, 1 set of water bath, 1 set of buffer cylinder, 1 set of heater, 2 sets of gas flow meters, 2 vortex jet fans, 1 set of temperature control system, 1 set of cooler, 1 set of cooling system, 1 set of fire-retardant buffer box, 6 sets of temperature control sensors, 6 sets of manual sampling ports, 6 controllers, 1 set of methyl acetylene gas and cylinder (8 liters), 1 pressure reducer, 1 electric control box, leakage protection switch, push button switch, 1 batch of st*nless steel connecting pipes and ball valves, st*nless steel bracket with movable wheels |
ZR-581-II Data Acquisition Activated Carbon Adsorption Tower |
M*n parameters and configuration: experimental gas volume 10~15m3/h, SO2 purification efficiency greater than 95%, activated carbon adsorption tower size Φ100×1000 mm, device dimensions: length 1200mm width 400mm height 1800mm, power supply: 220V power 500W, configuration: 1 set of microcomputer SO2 inlet and outlet concentration detection, 1 set of wind pressure detection, 1 set of 11-inch color LCD touch screen, 1 set of data processing and analysis system, 1 communication interface, 1 set of online temperature and humidity detection, 1 set of micro printer, including 1 set of small organic glass activated carbon gas generating device, 1 set of three-stage activated carbon adsorption tower, 1 set of activated carbon filler, 1 fan, 1 gas flowmeter, 1 set of SO2 gas and cylinder (10 liters), 1 pressure reducer, 1 SO2 gas flowmeter, 1 electric control box, leakage protection switch, push button switch, PVC connecting pipes and ball valves, 1 batch, st*nless steel bracket with movable wheels, etc. |
ZR-581-II Data Acquisition Activated Carbon Pressure Swing Adsorption Device |
M*n parameters and configuration: adsorption efficiency 90%, gas processing volume: 2-4m3/h, st*nless steel adsorber outer diameter: Φ100mm height 1000mm, regeneration heater power: 2kw, device dimensions: 1800×500×800 mm, power supply 220V power 3000W, configuration: 1 set of microcomputer methyl methacrylate gas inlet and outlet concentration detection, 1 set of online wind pressure detection, 1 set of online temperature and humidity detection, 1 set of LCD display, 1 set of data processing and analysis system; 1 set of computer communication interface, 1 set of micro printer, 1 set of st*nless steel pressure swing adsorption tower, 1 set of heater, 1 set of gas flow meter, 1 fan, 1 set of temperature control system, 1 set of temperature control sensor, 1 set of methyl methacrylate gas and cylinder (8 liters), 1 pressure reducer, 1 electric control box, leakage protection switch, push button switch, 1 batch of st*nless steel connecting pipes and ball valves, st*nless steel bracket with movable wheels |
Wechat scan code follow us
24-hour hotline+86 18916464525
Phone18916464525
ADD:Factory 414, District A, No. 6, Chongnan Road, Songjiang Science and Technology Park, Shanghai ICP: Sitemap