High -concentration organic wastewater treatment experimental device,Dynamic static experimental device
1. Experimental principles and purposes:
1. Experimental purpose:
1. Understand the process of high concentration of organic wastewater treatment.
2. Deepen the understanding of the basic concepts of the experiment and improve theoretical and practical knowledge.
2. Experimental principle:
High -concentration organic wastewater is generally treated with lift -type anaerobic sludge reactors. Referred to as UASB bioreactor. There is a carrier inside this reactor, which is a suspended growth type of anaerobic digestion. The sludge layer with a high sludge concentration at the bottom of the reactor is called a sludge bed, and the sludge layer with a slightly lower sludge concentration in the sludge bed is called a sludge floating layer. The sludge bed and the sludge suspension layer are collectively referred to as the reaction area.
In the state of anaerobic, the biogas produced by microorganisms has a strong stirring during the rise process, which is conducive to the formation and m--ntenance of granular sludge. The wastewater enters the bottom of the reactor uniformly, and the sewage is upward through the sludge bed cont--ning granular sludge or flocculent sludge, and anaerobic reactions occur during contact with the sludge particles. Three -phase separator. The sludge particles of biogas balp and biogas 0 foam rose to the top of the reactor to the bottom of the gas reflective plate. The biogas bolt is collected to the top of the reactor to warm the water tank, and it is discharged after being measured by wet flow.
2. M--n technical indicators and parameters:
1. Environmental temperature: 5 ~ 40 ℃
2. Treatment of water: 5L ~ 10L/H
3. Design and water quality: (take high concentration of wastewater in pharmaceuticals as an example)
4. Device shape size: 1600mm × 500mm × 2300 mm
5. Work power: AC220V ± 10%, 50Hz, single -phase three -line system, power of 1500W, safety protection: ground protection, leakage protection, overcurrent protection
High -concentration organic wastewater treatment experimental device,Dynamic static experimental device
1. Function and characteristics:
The bolt group connects the experimental device to perform experiments such as bolt static stress, deformation, stiffness, axial load, pre -tightening tightening, and other experiments.
Special test analysis software can perform related detection of bolt static and dynamic, and can compare the measured and simulation curve, and the curve can be printed.
All tested elements adopt a full bridge test circuit, and each str--n testing structure is stable, repetitive, and high accuracy.
A single -phase AC motor (220V power supply) is used to start the motor for a dynamic bolt experiment.
Dedicated test analysis software has multimedia teaching functions. Students can expl--n the experiments by experiments in the software and edit the test report through the software.
2. Experimental purpose
1. Understand the stress situation of the bolt connection during the tightening process.
2. Calculate the relative rigidity of the bolt and draw the stress deformation diagram of the bolt connection.
3. When verifying the load of the axial direction, the deformed rule of the pre -tightening bolt is connected, and the impact on the total pull force of the bolt.
4. Through the dynamic carrier experiment of the bolt, change the relative stiffness of the bolt connection, observe the changes in the amplitude of the bolt, to verify the measures that increase the intensity of the bolt connection.
3. Experimental project
1. Basic bolts connect to quiet dynamic experiments.
2. Increase the static and dynamic experiments of the bolt rigidity.
3. Increase the static and dynamic experiments of the rigidity of the connection.
4. Use the static and dynamic experiment of elastic pads.
Wechat scan code follow us
24-hour hotline+86 18916464525
Phone18916464525
ADD:Factory 414, District A, No. 6, Chongnan Road, Songjiang Science and Technology Park, Shanghai ICP: Sitemap