PRODUCT CENTER

DYHGRG-20 heat pipe heat exchanger training device

Release time:2024-06-13 05:30viewed:times
  • DYHGRG-20 heat pipe heat exchanger training device
Technical parameters:
1. Input power: single-phase AC220V±10% 50Hz, power 500W.
2. Low-noise axial flow fan, power: 100W, flow rate: 300 m3/h.
3. Pitot tube flowmeter with inclined tube micromanometer to measure flow rate: range -10-700pa.
4. The diameter of the cold and hot end velocity measurement section duct is Φ89mm; finned (aluminum rolled tube) heat pipe heat exchanger, size Φ20×350mm, material copper tube.
5. Temperature measurement: The measurement system is equipped with an intelligent temperature control instrument (PID temperature control, accuracy ±0.2℃), and a high-precision PID voltage regulation module circuit.
6. Dimensions: 1000×400×800mm, the appearance is a st*nless steel bracket.
7. Virtual simulation software for electrical installation of building buildings and intelligent buildings Based on unity3d design, users can choose different sizes of interactive interfaces according to computer configuration, and can choose six levels of image quality. The model in the software can be rotated 360°, enlarged, reduced, and translated. There are assistant prompts during the use of the software, as follows: A. Wet alarm system 1. System overview: Overview of wet alarm system 2. Equipment recognition: It has the best viewing angle, equipment det*ls (displaying the introduction or parameters of the equipment), exercises (6 built-in multiple-choice questions, with prompts for correct and incorrect choices), and schematics (you can enter the equipment from the schematics). The equipment includes: sprinklers, water flow indicators, signal butterfly valves, exhaust valves, fire alarm controls, high-pressure gauges, high-level water tanks, Wia control cabinets, pressure regulators, flow switches, terminal water testing devices, dr*nage facilities, water pump connectors, hydraulic alarms, delays, wet alarms, butterfly valves, check valves, fire pumps, safety pressure regulators, and fire water tanks. 3. Principle display: Display the working principle of the wet alarm system, 3D animation demonstration, and semi-transparent 3D models, so you can see the internal water flow. Equipped with practice module (built-in 4 multiple-choice questions, with prompts for correct and wrong choices) 4. Design layout: There are multiple-choice questions and calculation questions, each of which is scored, and the correct answer and score will be displayed after submission B. Gas fire extinguishing system 1. System overview: Overview of gas fire extinguishing system 2. Equipment cognition: It is equipped with the best viewing angle, equipment det*ls (displaying the introduction or parameters of the equipment), practice (built-in 8 multiple-choice questions, with prompts for correct and wrong choices), schematic diagram (you can enter the equipment from the schematic diagram). The equipment includes: nozzle, HFC-227 storage bottle, bottle head valve, heptafluoropropane check valve, high-pressure hose, gas check valve, safety valve, weighing alarm, electromagnetic starter, selection valve, smoke alarm, fire alarm controller. 3. Principle display: Display the working principle of the gas fire extinguishing system, 3D animation demonstration, 3D model is semi-transparent, and the internal gas can be seen. Equipped with a practice module (3 multiple-choice questions built in, with prompts for correct and incorrect choices) 4. Design layout: There are 6 multiple-choice questions, each with a score, and the correct answer and score will be displayed after submission C. Escape drill: Teaching in the form of fun games, escape from the burning room within a limited time, and wrong choices will directly enter the score interface. Experimental purpose: 1. Understand the structure of the heat pipe heat exchanger. 2. The heat transfer coefficient and thermal efficiency of the heat pipe heat exchanger can be calculated. M*n configuration: heat pipe heat exchanger, heating section *r duct, heating section *r duct, fan, Pitot tube flowmeter and differential pressure sensor , heating is steplessly adjusted by a solid pressure regulating module, universal signal input patrol meter displays temperature, pressure difference, ammeter, voltmeter, st*nless steel stand and control screen, etc.