dyHGRG-28 free convection cross tube external heat release coefficient test training device
Release time:2024-06-11 23:30viewed:times
Experimental purposes:
1. Determine the free motion heat release coefficient of a horizontal single tube.
2. Based on the similar analysis of free motion heat dissipation, sort out the criterion equation.
M*n configuration:
four electroplated copper tubes of different lengths and diameters, with heaters installed inside the tubes, solid voltage regulating modules for inorganic heating adjustment, temperature measurement sensors , digital display instruments for electric power testing, universal signal input inspection instruments to display temperatures, and each tube is equipped with There are temperature control instruments, st*nless steel benches and control panels.
Technical parameters:
1. Input power supply: single-phase AC220V±10% 50Hz, power 3.0KW.
2. Electroplated copper tube specifications: Φ80mm×1600mm, Φ60mm×1400mm, Φ40mm×1200mm, Φ25mm×1000mm.
3. The temperature is measured by a high-precision temperature sensor, and the high-precision 16-channel universal signal is input to the inspection instrument for display.
4. Overall dimensions: 1700×800×1600mm. The shape is a st*nless steel movable bracket with double brake wheels.
5. Virtual simulation software for electrical installation of building buildings and smart buildings. Based on unity3d design, users can choose different interactive interface sizes according to computer configuration, and six levels of image quality are av*lable. The model in the software can be rotated 360°, enlarged, reduced, and translated. There are assistant prompts during the use of the software, and the content is as follows: A. Wet alarm system 1. System overview: Overview of wet alarm system 2. Equipment awareness: equipped with the best viewing angle, equipment det*ls (displaying the introduction or parameters of the equipment), and exercises (Built-in 6 multiple-choice questions, prompts for correct and incorrect choices), schematic diagram (can be entered into the device from the schematic diagram). Equipment includes: nozzle, water flow indicator, signal butterfly valve, exhaust valve, fire alarm control, high pipe pressure gauge, high water tank, Wia control cabinet, pressure stabilizing tank, flow switch, terminal water testing device, dr*nage facilities, water pump connection alarms, hydraulic alarms, delayers, wet alarms, butterfly valves, check valves, fire pumps, safety pressure regulators, and fire pools. 3. Principle display: Show the working principle of the wet alarm system, three-dimensional animation demonstration, the three-dimensional model is translucent, and the internal water flow can be seen. Equipped with a practice module (built-in 4 multiple-choice questions, with prompts for correct and incorrect choices) 4. Design layout: There are multiple-choice questions and calculation questions, each question is scored, and the correct answer and score will be displayed after submission B. Gas fire extinguishing system 1. System overview: Overview of gas fire extinguishing system 2. Equipment awareness: equipped with the best viewing angle, equipment det*ls (displaying the introduction or parameters of the equipment), exercises (built-in 8 multiple-choice questions, with prompts for correct and incorrect choices), Schematic diagram (access to the device from the schematic diagram). Equipment includes: nozzle, HFC-227 storage bottle, bottle head valve, heptafluoropropane one-way valve, high-pressure hose, gas one-way valve, safety valve, weighing alarm, electromagnetic starter, selection valve, smoke alarm, fire Alarm controller. 3. Principle display: Show the working principle of the gas fire extinguishing system, three-dimensional animation demonstration, the three-dimensional model is translucent, and the internal gas can be seen. Equipped with a practice module (built-in 3 multiple-choice questions, with prompts for both correct and incorrect choices) 4. Design and layout: There are 6 multiple-choice questions, each question is scored, and the correct answer and score will be displayed after submission. C. Escape drill: adopted Teaching is conducted in the form of fun games. Escape from the burning room within a limited time. If you make a wrong choice, you will directly enter the score interface.